ALL  FOOTINGS  SHALL  RESTO             FIR  ,    ATURAL  SOIL  OR  APPRO  ED                              /,
             COMPAC  ED  FILL.        SOIL  BEA  ING  CAPACITY  ASSUMED  TO  BE  1000                                   2
             psf.

             PROVIDE  GROU  D  POISO  I  G  PER  FHA  MPS  815-3.6.

             PROVIDE  TERMITE . A JD  DECAY  PROTECTIO             PER  FHA  MPS  SECTIO
             815.


              CO  Cf'.E-'IE


              CONCRETE  SHALL  BE  PLACED  IN  ACCORDANCE  WITH  CHAPTER  26  OF
              THE  BUILDING  CODE.          IT  IS  TO  BE  MACHINE  MIXED  \11,  ITH  A  MAXIMUM
              OF  7  1/2  GALLONS  OF  WATER  PER  SACK  OF  CEME  T.              CONCRETE  TO
              REACH  A  STRENGTH  OF  2000  psi  MINIMUM,  I              28  DAYS.(FIVE  SACK
              MIX  GRADE  "B").


                                1
              FOU  DAT IO     A  D  FLOOR  SLABS  SHALL  BE  TREATED  AS  THOL;OJ  'lT E Y
              ARE  TO  BE  CO  STRUCTED  ON  EXPANSIVE  SOIL  (UNLESS  A  SOILS
              REPORT  IS  SUBMITTED  BY  A  QUALIFIED,  LICENCED,  CIVIL  ENG!  "EER
              INDICATING  A  SOILS  CONDITION  OTHER  THAN  EXPANSIVE  SOIL)  AND
              SHALL  CONFORM  AS  FOLLOWS:                                                                      EE

                      (A)  CONTINUOUS  F0C1IKGS  SHALL  BE  PROVIDEb  UNDER
                     EXTERIOR  WALLS  AND  INTERIOR  BEARING  WALLS
                     EXTENDING  BELOW  GRADE  24".

                      (B)  REINFORCING  STEEL  SHALL  CONSIST  OF  ONE
                     CONTINUOUS  NO.  4  BARS,  ONE  AT  3"  FROM  BOTTOM  AND
                     O~E  AT  3"  FROM  TOP  OF  FOUNDATION.

                      (C)  FLOOR  SLAB  SHALL  BE  A  MINIMUM  OF  4"  THICK  OVER
                     4"  CLEAN  AGGREGATE  BASE  AND  REINFORCED  WITH  NO.  3
                     BARS  AT  24"  0/C  BOTH  WAYS  OR  6  X  6  - 6/6  WELDED
                     WIRE  FABRIC.
                                                                                            I
                      (D)  SATURATE  THE  SOIL  18"  DEEP  BEFORE  PLACING  THE
                      CONCRETE  SLAB.

              MAINTAI    1   CONCRETE  SLAB  MI  IMUM  6"  ABOVE  FI  ISH  GRADE.
                                                   1
              REINFORCING  BARS  SHALL  BE  DEFORMED  BARS  cot  FOR~ING  TO
              R EQ U IRE MEN TS  OF  U . B . C .  ST AND ARD  2 6 - 7  AST M 6-1 5 - 4 0 .   M I  I MUM
              LAP  FOR  REINFORCING  STEEL  SHALL  BE  40  BAR  DIAMETERS  OR
              24-INCHES  MI  I  UM.


              SILL  BOLTS  SHALL  BE  1/2-INCH  DIAMETER  x  10"  ANCHOR  BOLTS  AND
              SHALL  BE  EMBEDDED  INTO  FOOTING  CONCRETE  A  MI  IMUM  OF  7".
              SPACING  SHALL  BE  AS  INDICATED  ON  DRAWINGS  BUT  NOT  TO  EXCEED
              4 8" .

              APPROVED  SHOT  PINS  MAY  BE  USED  FOR  INTERIOR,  ·ot EE-ARING
              WALLS.      SHOT  PINS  SHALL  BE  3"  LOG  WITH  CADMIUM  WASHERS
              (RAM  ET  #3348  - ICBO         1639  OR  ECUAL).